Plan Submittal
Guidelines
Single Family
Garage/Carport
Remember to always check with the
Planning Division at (925) 973-2560 to confirm zoning requirements prior to beginning your
project!
REQUIRED DOCUMENT SUBMITTAL
(Please provide three (3) complete sets)
address
of project; name, address & phone number of project owner; name,
address, phone number, (title & registration information) of project
designer; description of project; gross area of structure; height of
structure.
Original Signature (& wet
stamp) of Project Designer Is Required On All Drawings.
Plot Plan: (indicate
scale); lot dimensions; identification of all streets and
rights-of-way adjacent to the site; location of easements and visible
utilities; dimensions which indicate the distances from all existing and
proposed buildings to adjacent property lines, existing buildings, and
street curb (if applicable); driveway slope; north arrow; location of all
driveways and site entrances.
Grading/Drainage Plan:
tops & toes of slopes; grade/pad elevations, ground slope drainage
scheme & topographical details; retaining walls & drainage
systems.
Architectural Plans: (indicate
scale); exterior building elevations; floor plan identifying use of
structure; dimensions of garage and parking stall(s); location of water
heater and other fixed utilities; building sections; details of all
fire-rated assemblies; stairway, handrail & guardrail details;
flashing details; roof covering specifications; exterior wall covering
specifications, color, etc.
Structural
Plans: (indicate scale); footing/foundation plan; floor framing
plan; roof framing plan; structural frame details; manufactured truss
diagrams stamped & signed by design engineer (including ID #'s and
splice & connection details); structural material specifications; etc.
Electrical Plans: complete
electrical plans which identify the location and capacity of the main site
service panel and all sub panels and show the location of all receptacles,
switches, lighting fixtures, etc.
Plumbing
Plans & Mechanical Plans: if proposed, provide complete plans
sufficient to show the size and location of all plumbing & mechanical
fixtures, appliances, piping, tubing, venting, etc.; indicate whether
appliances are gas-operated, electric, or otherwise; etc.
CALCULATIONS - 2 SETS:
structural wind load design factor is 70 M.P.H.
- exposure "C"; seismic zone 4.
|